WE PROVIDING CUSTOMER SATISFACTION THROUGH QUALITY PRODUCTS

Our Products

SVG – (Static Var Generator)

The working principle of the STD SVG series static var generator is to connect a voltage-type inverter in parallel to the power grid through a filter. By adjusting the amplitude and phase of the AC side output voltage of the inverter, it can dynamically control the reactive power in the power grid system for accurate compensation, the instantaneous response time ¡s Less than 5Ous, and the full response time is Less than l0ms, avoiding overcompensation and under compensation. It is currently the best solution in the field of reactive power compensation.

Specifications

Product model and definition
STD SVG 0.4 50k 4L W
Enterprise code Static var generator Voltage level
0.22: 220V
0.4: 400V
0.5: 500V
0.69: 690V
Rated Capacity (kvar)
5/15/35/50/75/100kvar
2L: SingLe-phase
3L: Three-phase
three-wire
4L: Three-phase
four-wire
W: Wall-mounted
R: Rack mount
C: Cabinet
Technical Specification
Item
Product number
220V series 380V series 500V series 690V series
Altitude <2000m, above 2000m, derate according to GB/T3859.2
Ambient temperature -20 +50°C
Relative humidity <90%, no condensation on the surface when the monthly minimum temperature is 25°C
Pollution level Level III below
Operating Voltage AC22OV±20% AC38OV±20% AC500V±20% AC69OV±20%
working frequency 5OHz±5%
Compensation current 25A 25/50/75/100/150A 100A 100A
Grid structure L/N 3P3W/3P4W 3P3W/3P4W 3P3W/3P4W
Number of units connected in paralleL Unlimited
Overall machine efficiency >97%
Grid structure 32kHz 16kHz 12.8kHz 12.8kHz
Compensation range 2 – 50times, single compensation rate is adjustable
Function selection Reactive power Reactive power, reactive power + asymmetry
Reactive power compensation rate >95% >92%
Neutral filtering capability Neutral Line filtering capability is 3 times that of phase filtering capability
Full response time <4Oms <4Oms <4Oms
noise <60dB <60dB <65dB <65dB
control method 2-way RS485 interface (supports GPRS/WIFI)
noise <60dB <60dB <65dB <65dB
Protection Overload, software/hardware overcurrent, grid overvoltage and undervoltage, power failure, overtemperature, frequency abnormality protection, etc. Overload, software/hardware overcurrent, grid overvoltage and undervoltage, grid voltage imbalance, power failure, overtemperature, frequency abnormality, short circuit protection, etc.
Installation method Rack/wall-mounted Rack
Incoming line Back incoming (rack type)
upper incoming (wall-mounted)
Back incoming line
Protection level 1P20

Models

Models
Model number Compensation
Capacity (kvar)
System voltage (V) Dimensions (D*W*H) Cooling Method
STD SVG-0.4-15k/4L-R 15 400 460*490*89mm Forced air cooling
STD SVG-0.4-35k/4L-R 35 400 460*490*89mm
STD SVG-0.4-50k/4L-R 50 400 500*510*190mm
STD SVG-0.4-75k/4L-R 75 400 500*550*240mm
STD SVG-0.4-100k/4L-R 100 400 500*550*240mm
STD SVG-O.5-90k/4L-R 90 500 495*675*275mm
STD SVG-O.69-120k/4L-R 120 690 495*675*275mm
Cabinet Device Model
Model number Compensation
Capacity (kvar)
System voltage (V) Dimensions (D*W*H) Cooling Method
STD SVG-O.4-200k/4L-C 200 400 1000*1000*2200mm Forced air cooling
STD SVG-O.4-250k/4L-C 250 400 1000*1000*2200mm
STD SVG-O.4-300k/4L-C 300 400 1000*1000*2200mm
STD SVG-O.4-400k/4L-C 400 400 1000*1000*2200mm
STD SVG-O.5-270k/4L-C 270 500 1000*1000*2200mm
STD SVG-O.69-360k/4L-C 360 690 1000*1000*2200mm

Features

  • Use DSP+CPLD all digital control core, three-level topology technology, advanced reactive power detection algorithm and PWM control strategy to achieve dynamic and accurate compensation of reactive power.
  • Adopt modular design, which facilitates parallel connection of multiple modules, takes small space and is easy to maintain.
  • The structural design of independent air ducts and independent warehouses ensures the stable operation of the equipment.
  • Carry out full-range dynamic compensation for inductive reactive power and capacitive reactive power, and solve the three-phase unbalance problem at the same time.
  • The dynamic response speed to the load is at the millisecond level, which can achieve dynamic and accurate compensation for the reactive power of impact loads.

 Catlog